DataTrak Operation
311238G 11
Table 1: Diagnostic Codes
Symbol Code
No.
Code Name Diagnosis Cause
Runaway Pump running faster than set runaway
limit.
Increased air pressure.
Increased fluid output.
Exhausted fluid supply.
E-1 Diving Up Leak during upstroke. Worn piston valve or packings.
E-2 Diving Down Leak during downstroke. Worn intake valve.
E-3 Low Battery Battery voltage too low to stop
runaway.
Low battery. To replace battery, see
page 12.
E-4 Service
Component 1
Problem with stopping runaway. Damaged solenoid.
Damaged valve carriage.
E-4 Disconnected
Solenoid
Solenoid is disconnected. Solenoid unplugged.
Damaged solenoid wires.
E-5 Service
Component 2
Problem with sensing valve movement. Sensors unplugged.
Sensors mounted incorrectly.
Damaged sensors.
Damaged valve carriage.
E-6 Blown Fuse Fuse is blown. Faulty solenoid or solenoid wiring.
Extreme temperatures (above 140°F
[60°C]).