Integrated Flow Control
72 312779E
Flow Control Setup
1. Install the intrinsically safe flow regulator (FC) as
explained in the ProMix 2KS Installation Manual.
2. Ensure that the analog signal is 0-10 Vdc, or is
properly provided through network communication.
3. Calibrate the system’s flow meters; see page 100.
This ensures that the K-factors are tuned to the
range of materials being used.
4. Verify that the I/O inputs are working properly. If
using discrete I/O, check by viewing Advanced
Setup Screen 6 and Advanced Setup Screen 7,
page 42. If using network communication, ensure
the commands are being sent by viewing the Status
Screen, page 24, and Advanced Setup Screen 6
and Advanced Setup Screen 7, page 42, for
inputs.
NOTE: See the Graco Gateway manual for Flow Control
Modbus addresses.
5. See Flow Control Startup.
Flow Control Startup
1. Set Flow Control toOn in Configure Screen 5.
2. In Advanced Setup Screen 1, turn Manual Over-
ride On. The Flow Control Override field will appear.
F
IG
. 77. Configure Screen 5
F
IG
. 78. Advanced Setup Screen 1