Troubleshooting
Error Error
Error
Location Location
Location
Type Type
Type
Description Description
Description
Cause Cause
Cause
Solution Solution
Solution
Looseconnection
ortrippedcircuit
breaker.
Checkwiringforlooseconnectionor
trippedcircuitbreaker.
V2MH
TCM
LowVoltage
Hose
Lowincomingline
voltage.
Measurevoltageatcircuitbreakerand
ensurevoltageisgreaterthan195
VAC.
V3IT
TCM
HighVoltage
CAN
Bad24VDCpower
supply.
Checkvoltageofpowersupply.
Voltageshouldbe23-25VDC.Ifoutof
tolerance,replacepowersupply.
Incomingline
voltageistoohigh.
Ensureincomingsystempoweris
wiredproperly.Verifyvoltageateach
circuitbreakerisbetween195and
264VAC.
V3MA
TCM
HighVoltageA
Generatorisset
toahigh-legdelta
con󰘰guration.
Ifthegeneratoriswiredinahigh-leg
deltacon󰘰gurationandisconsistently
causingthiserror,changegenerator
con󰘰gurationto208VACwye(star).
ContactGracoTechnicalAssistance.
Incomingline
voltageistoohigh.
Ensureincomingsystempoweris
wiredproperly.Verifyvoltageateach
circuitbreakerisbetween195and
264VAC.
V3MB
TCM
HighVoltageB
Generatorisset
toahigh-legdelta
con󰘰guration.
Ifthegeneratoriswiredinahigh-leg
deltacon󰘰gurationandisconsistently
causingthiserror,changegenerator
con󰘰gurationto208VACwye(star).
ContactGracoTechnicalAssistance.
V3MH
TCM
HighVoltage
Hose
Incomingline
voltageistoohigh.
Ensureincomingsystempoweris
wiredproperly.Verifyvoltageateach
circuitbreakerisbetween195and
264VAC.
V4CMMCM
HighVoltage
MCM
Incomingline
voltageistoohigh.
Ensureincomingsystempoweris
wiredproperly.Verifyvoltageateach
circuitbreakerisbetween195and
264VAC.
V4IT
TCM
HighVoltage
CAN
Bad24VDCpower
supply.
Checkvoltageofpowersupply.
Voltageshouldbe23-25VDC.Ifoutof
tolerance,replacepowersupply.
V4MA
TCM
HighVoltageAIncomingline
voltageistoohigh.
Ensureincomingsystempoweris
wiredproperly.Verifyvoltageateach
circuitbreakerisbetween195and
264VAC.
V4MB
TCM
HighVoltageBIncomingline
voltageistoohigh.
Ensureincomingsystempoweris
wiredproperly.Verifyvoltageateach
circuitbreakerisbetween195and
264VAC.
V4MH
TCM
HighVoltage
Hose
Incomingline
voltageistoohigh.
Ensureincomingsystempoweris
wiredproperly.Verifyvoltageateach
circuitbreakerisbetween195and
264VAC.
333024S 37

Other manuals for Graco Reactor 2 E-30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco Reactor 2 E-30 and is the answer not in the manual?

Graco Reactor 2 E-30 Specifications

General IconGeneral
BrandGraco
ModelReactor 2 E-30
CategoryPaint Sprayer
LanguageEnglish

Related product manuals