Troubleshooting
Error Error
Error
Location Location
Location
Type Type
Type
Description Description
Description
Cause Cause
Cause
Solution Solution
Solution
Incorrectsoftware
version.
InsertasystemtokenintotheADM
moduleandcyclethepower.Wait
untiltheuploadiscompletebefore
removingthetoken.
WBC0MCMSoftware
VersionError
MCMdoesnot
havelinevoltage.
IfV1CMalsoexists,see
troubleshootingforV1CM.The
softwareversioncannotbereadifthe
MCMdoesnothavelinevoltage.
WMC0TCMSoftware
Update
Required
TCMsoftwaremust
beupdatedtouse
HoseResistance
Mode.
UpdatetheADMwithsoftware
version4.01.001ornewer.See
UpdateADMSoftware,page78.
WMI0
TCM
TCMFanErrorFaninsideTCM
isnotoperating
properly.
CheckfordebrisintheTCMfanand
clearwithforcedairifnecessary.
WSUXUSBConguration
ErrorUSB
Avalid
congurationle
can'tbefoundfor
theUSB.
InsetasystemtokenintotheADM
andcyclepower.Waituntilthelights
ontheUSBportstopashingbefore
removingtoken.
WXUDADM
USB
Download
Error
Logdownload
failed.
BackupandreformattheUSBdrive.
Retrydownload.
WXUUADM
USBUpload
Error
Customlanguage
lefailedtoupload.
PerformnormalUSBdownloadand
usethenewdisptext.txtletoupload
thecustomlanguage.
Hosesection
removedor
replacedwithout
re-calibration.
Re-calibratethehose.Followthe
CalibrationProcedure,page72.
Z1DHHoseLow
Resistance
HoseWire
Hosewire
temperatureistoo
low.
Ensurehosewiretemperatureis
above–4°F(-20°C).
Hosesection
addedor
replacedwithout
re-calibration.
Re-calibratethehose.Followthe
CalibrationProcedure,page72.
Z4DHHoseHigh
Resistance
HoseWire
Hosewire
temperatureistoo
high.
Ensurehosewiretemperatureis
below221°F(105°C).
Z6DHHose
SensorError
HoseWire
TCMisunableto
sensehosewire
resistance
•Ensureatleast50ft(15.2m)of
heatedhoseisconnectedtothe
system.
•Iftheerrorcannotbeclearedor
theerrorregeneratesconsistently,
replacetheTCM.
38 333024S