Troubleshootin
g
Error Location Type Description
Cause Solution
Cold chemical
in
unheated port
ion
of system pass
ed
hose FTS at
startup.
Recirculate heated chemical back
to drum in cold conditions before
startup.
T2DH Hose Low
Temperature
Hose
Flow is too high at
current setpoint.
Use a smaller mix chamber that
isratedfortheunitinuse. If
recirculating, decrease flow or
decrease temperature setpoint.
Recirculat
e fluid through heaters
until inle
t fluid temperature is above
defined err
or level.
T2FA
MCM
Low
Temperature
Inlet A
Inlet fluid
temperatu
re is
below the d
efined
level.
Increase the low temperature
deviation level on the System Setup
screen.
Recircul
ate fluid through heaters
until in
let fluid temperature is above
defined e
rror level.
T2FB
MCM
Low
Temperature
Inlet B
Inlet flui
d
tempera
ture is
below th
e defined
level.
Increase the low temperature
deviation level on the System Setup
screen.
Hose setpoint higher than A and B
setpoints. Decrease hose setpoint.
T3CH
Hose
Hose Cu
tback
Hose current has
been reduced
because hose
has been
drawing current
for an extended
period.
Hose FTS is in a colder environment
than the rest of the hose. Expose
FTS to the same environment as the
rest of the hose.
High
ambient
temp
erature.
Ensu
re ambient temperature is below
120°
F (48° C) before using the
syst
em.
Enclosure fan not
operating.
Ensure fan in electrical enclosure is
spinning. If it is not, check fan wiring
or replace fan.
T3CT TCM TCM Cutback
Module fan not
operating.
If a TCM fan error (WMI0) has
occurred, fan inside the module is not
working properly. Check TCM fan
for debris and clear with forced air if
necessary.
T
3CM
M
CM
M
CM
T
emperature
C
utback
Motor control
temperature is
too high.
Ensure ambient temperature is below
120° F (48° C).
V
erify that all fans are working.
30 333024N

Other manuals for Graco Reactor 2 E-30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco Reactor 2 E-30 and is the answer not in the manual?

Graco Reactor 2 E-30 Specifications

General IconGeneral
BrandGraco
ModelReactor 2 E-30
CategoryPaint Sprayer
LanguageEnglish

Related product manuals