Troubleshooting
Error Location Type Description
Cause Solution
EVCH
ADM
Manual Hose Mode
Enabled
Manual hose mode
has been enabled
in System Setup
screen.
Install a functioning uid
temperature sensor (FTS)
on the hose. Manual hose
mode will automatically turn
off.
EAUX ADM
USB Busy USB drive has
been inserted to
the ADM.
Do not remove USB drive
until download/upload is
complete.
EVSX HCM Standby System has
entered standby .
Trigger gun to resume
spraying.
Turn off standby in setup
screens.
EVUX ADM
USB disabled USB
download/uploads
are disabled.
Enable USB download/up-
loads on the Advanced
Setupscreenbeforeinsert-
ing a USB drive.
H2MA Heater A Low Frequency A
Line frequency is
below 45 Hz
Ensu re line frequency of
incoming power is between
45and65Hz.
H2MB Heater B Low Frequency B
Line frequency is
below 45 Hz
Ensu re line frequency of
incoming power is between
45and65Hz.
H2MH Hose Low Frequency Hose
Line frequency is
below 45 Hz
Ensu re line frequency of
incoming power is between
45and65Hz.
H3MA Heater A High Frequency A Line frequency is
above65Hz
Ensu re line frequency of
incoming power is between
45and65Hz.
H3MB Heater B High Frequency B
Line frequency is
above65Hz
Ensu re line frequency of
incoming power is between
45and65Hz.
H3MH Hose High Frequency
Hose
Line frequency is
above65Hz
Ensu re line frequency of
incoming power is between
45and65Hz.
22
334946A