Troubleshooting
Error Location Type Description
Cause Solution
L1AX ADM
Low Chemical Level
A
Low material level.
Refill material and update
drum level on A DM
Maintenance screen.
Alarmcanbedisabledon
the System Setup screen.
L1BX ADM
Low Chemical Level
B
Low material level.
Refill material and update
drum level on A DM
Maintenance screen.
Alarmcanbedisabledon
the System Setup screen.
MMUX
USB
Maintenance Due -
USB
USB logs have
reached a level
where data loss
will occur if logs are
not downloaded.
InsertaUSBdriveintothe
ADM and download all logs.
Pressure
difference between
A and B material
is greater than the
defined value.
Ensure material ow is
equally restricted on both
material lines.
Pressure
imbalance is
defined too low.
Ensure that the pressure
imbalance value, on the
System Setup screen, is at
an acceptable maximum
pressure to prevent
unnecessary alarms and
abort dispenses.
Out of material.
Fill tanks with material
Fluid leaking from
heater in let rupture
disk.
Check if heater
and PRESSURE
RELIEF/SPRAY valve are
plugged. Clear. Replace
rupture disk. Do not replace
withapipeplug.
P0AX
HCM
Pressure Imbalance
A High
Feed system
defective.
Checkfeedpumpand
hoses for blockage. Check
that feed pumps have
correct air pressure.
334946A 23