Electrical Schematics
HCM Schematic
To TCM
CB11 CB12 CB13 CB14 CB15
HOSE
MOTOR A HEAT B HEAT TRANS
PE
1
Ground
Bar 17G653
For 3 phase Motor: 17G688 / For Single phase Motor: 17G693
To CT01
17G689
Motor Power
Motor Over Temperature Switch
24T050
16W130
16W130
B Inlet
A Inlet
16X118
To Power Supply
24R735
127068
A Pressure Transducer
B Pressure Transducer
Fluid Manifold
B Inlet Pressure /
Temperature Transducer
A Inlet Pressure /
Temperature Transducer
WHITE
ORANGE
GREEN
BLACK
RED
17G670
91
17G671
24Y263
HCM
17G605
17G669
17G690
3
2
ti26608a
17G667
1
See Replace HCM, page 66 for setting the rotary
switch position.
2
Connect the blue and brown wires to the motor
over-temperature wires inside the motor junction box.
3
Three pole version of CB12 shown. H-30 and H-XP2
uses a two pole version of CB12.