EasyManua.ls Logo

Graco Reactor 2 H-30 - TCM Schematic

Graco Reactor 2 H-30
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical Schematics
TCM Schematic
1
15D906
24U855
CB11 CB12 CB13 CB14 CB15
HOSE
MOTOR A HEAT B HEAT TRANS
24X648 (15kW, 20kW),
24T242 (10 kW)
Overtemperature Switchs
BLKBLK
RED
TB21 / 17B856
TB31
17D780
To TB03
To TB02
10kW - 17G685
15k, 20kW - 17G686
To HCM
To ADM
To Ground Bar
To Ground
Bar
To Heated
Hose
2
24W204
A RTD
B RTD
B HEATER
A HEATER
Transformer Fan
24R756
Hose Transformer
127290
127068
127068
TCM
ti26607a
3
4
To Hose
RTD
1
Locate near TCM.
2
Dire
ct connect heater elements to TCM for 15kW
and 2
0kW systems. Harness 17G684 and spice
conn
ectors (255716) used for 10kW systems.
3
Terminal block TB21 only used in 15kW and 20kW
systems. Use splice connectors 255716 for 10kW
systems.
4
Torque to 3545 in.-lbs. (4–5 N•m).
98 334946A