Setup
Install Install
Install
Fluid Fluid
Fluid
Temperature Temperature
Temperature
Sensor Sensor
Sensor
TheFluidTemperatureSensor(FTS)issupplied.
InstallFTSbetweenmainhoseandwhiphose(see
yourheatedhosemanual).
Connect Connect
Connect
Heated Heated
Heated
Hose Hose
Hose
to to
to
Proportioner Proportioner
Proportioner
NOTICE NOTICE
NOTICE
Toavoiddamagetothehose,onlyconnectReactor
2proportionerstogenuineGracoheatedhoses.
Refertoyourheatedhosemanualfordetailed
connectioninstructions.
1.Turnoffmainpowerswitch(MP).
2.Removecover(CV).
3.Forproportionerswithelectricalspliceconnectors
(S):
a.Connecthosepowerwirestoelectricalsplice
connectors(S)fromproportioner.Wrap
connectorswithelectricaltape.
4.Routeheatedhosewires(HW)throughstrain
relief(SR)andinstallwiresintotheopenscrew
terminalsontheterminalblock(TB).Torqueto
35in-lb(3.95N•m).
5.Reinstallcover(CV).
334945J 33