Important Two-Component Material Information
10 312066ZAD
Foam Resins with 245 fa
Blowing Agents
Some foam blowing agents will froth at temperatures above
90°F (33°C) when not under pressure, especially if agitated.To
reduce frothing, minimize preheating in a circulation system.
Changing Materials
NOTICE
Changing the material types used in your equipment
requires special attention to avoid equipment damage
and downtime.
When changing materials, flush the equipment
multiple times to ensure it is thoroughly clean.
Always clean the fluid inlet strainers after flushing.
Check with your material manufacturer for chemi-
cal compatibility.
When changing between epoxies and urethanes
or polyureas, disassemble and clean all fluid com-
ponents and change hoses. Epoxies often have
amines on the B (hardener) side. Polyureas often
have amines on the B (resin) side.