Troubleshooting
14 309585A
Speed of application slow or slower Material too thick Thin material.
Nozzle too small Change nozzles to a larger size. See
Recommended Nozzle Selection
Chart, page 10.
Too much air being used. Partially close gun air valve to reduce
air flow.
Flow control (RTX 1000 model) set
too low
Increase flow control setting
Pump hose worn Replace hose.
Plugged or dirty gun Relieve Pressure, page 5. Clean
gun.
Kinked hose Unkink hose.
Gun adjustment set too low Increase flow adjustment with flow
adjustment nut.
Intermittent flow/sputtering Hopper connection not tight Check gasket. TIghten connection.
Debris in system Clean
Quick disconnect does not stay con-
nected.
Dirty or corroded fitting Clean thoroughly. Soak in oil. Apply a
few drops of light oil.
Gun will not shut off Worn nozzle or needle. Relieve Pressure, page 5. Replace
worn parts.
Debris in needle passage Relieve Pressure, page 5. Clean.
Fluid leaking at Flow Adjustment Nut Damaged seal. Relieve Pressure, page 5. Replace
seal.
Fluid leaking out of either plug Missing or damaged o-rings Relieve Pressure, page 5. Replace
o-rings.
Gun damaged Replace gun
Needle adjustment won’t adjust Dirty threads Clean threads
Nozzle not on gun Put nozzle on gun
Problem Cause Solution