Service
46 312780K
Replacing Air Filter Element
Check the 5 micron air manifold filter daily and replace
element (317a, Part No. 15D909) as needed.
1. Close main air shutoff valve on air supply line and
on unit. Depressurize air line.
2. Remove filter cover (A). See F
IG. 19.
3. Unscrew filter bowl (B).
4. Remove and replace element (317a).
5. Screw filter bowl (B) on securely. Install cover (A).
Wall Mount Fluid Station
Preparation
1. Follow Before Servicing, page 40.
2. Loosen the 4 screws (307), then remove the Wall
Mount Fluid Station cover (322). F
IG. 20.
Removing a pressurized air filter bowl could cause
serious injury. Depressurize air line before servicing.
F
IG. 19: Replacing Air Filter Element
317a
A
B
TI13069a
TI12691a