17309251
Pressure Control Repair
Stored Data (Not available on all sprayers)
The SmartControl contains stored data to assist with troubleshooting and maintenance. To view this stored data on
the digital display, proceed as follows:
1.
Relieve pressure; page 4.
2. Plug in sprayer.
3. Hold down display button and turn sprayer ON.
4. Release display button about 1 second after
turning on sprayer.
Sprayer model number displays (U695, U795, etc.) for
a few seconds and then data point 1 is displayed.
5. Push display button and next data point displays.
6. Turn sprayer OFF and then ON to leave stored
data mode.
Data Point Definition
1 Number of hours power switch has been ON with power applied
2 Number or hours motor has been running
3 Number of hours sprayer has been above 500 psi with power applied
4 Not used
5 Last recorded Error Code E=XX. See Error Code messages on page 18.
6 Control board software revision number
Note: Gallon/liter counter resets to zero at 65,000 gallons (245 700 liters)