Grounding
310743A 7
Grounding
Check your local electrical code and pump/sprayer manual for detailed grounding instructions.
• Spray gun: ground through connection to a grounded fluid hose and pump/sprayer.
• Fluid hose: use only grounded hoses.
• Fluid supply container: follow local code.
• Object being sprayed: follow local code.
WARNING
Read warnings, page 3.
• Solvent flushing pails: follow local code. Use only con-
ductive metal pails placed on a grounded surface. Do
not place pail on a non conductive surface, such as
paper or cardboard, which interrupts grounding continu-
ity.
TI11021
TI11022
• To maintain grounding continuity when flushing or
relieving pressure: hold metal part of gun firmly to side
of grounded metal pail, then trigger gun.
TI5047A
TI5046A