Flushing
18 310743A
Flushing
Flush pump and gun before fluid can dry in it. If available, use flushing procedure provided in your pump or sprayer
manual instead of this procedure.
d. Remove and clean GHD RAC spray tip.
WARNING
Read warnings, page 3.
TI5183A
1. Follow Pressure Relief Procedure, page 10. Engage trig-
ger lock.
TI5046A
TI5049A
2. Remove tip guard and spray tip. Clean with solvent. See
page 15.
TI5183A