NOTICE
Do not allow pump to run dry. It will quickly
accelerate to a high speed causing damage.
1. Prime. See Prime, page 17.
2. Follow Pressure Relief Procedure, page 14.
3. Install tip and tip guard on gun.
4. Open bleed type master air valve (B).
5. Turn regulator adjustment knob (G) until gauge
(E) reads desired pressure. Turn clockwise to
increase pressure, counterclockwise to decrease
pressure.
6. Disengage gun trigger lock.
7. Spray a test pattern. Read uid manufacturer’s
recommendations. Adjust pressure as
necessary. If using an AA gun, increase gun air
pressure while testing spray pattern.
8. Flush when done spraying. See Flush, page 15.
9. Follow Pressure Relief Procedure, pag e 14.
Shutdow
n
NOTICE
Never
leave water or water-base uid in pump over
night
. If you are pumping water-base fluid, flush
with w
aterrst,thenwitharustinhibitor,suchas
miner
al spirits. Relieve pressure, but leave rust
inhib
itor in pump to protect parts from corrosion.
Foll
ow Pressure Relief Procedure, page 14.
Always flush the pump before the fluid dries on the
displacement pump rod. See Flush, page 15.