User menu
User menu overview:
Menu access P + 1
+ /
-
Description
1. Dry refrigeration DC ON/OFF Activation of dry refrigeration.
(on/off)
2. Rapid thaw UF ON/OFF Activation of rapid thaw. (on/off)
3. Local alarm setting LAL LHL °C Setting the upper alarm limit. At
alarm, the display shows:
A2
LHd min. Time delay for the upper alarm
limit.
DA On/off Activation of local door alarm. At
alarm, the display shows: A1
(1=on / 0=off)
DAd min. Time delay for the door alarm.
BU On/off Activation of buzzer. The buzzer
sounds at alarms A1, A2. (1=on /
0=off)
4. External alarm
setting
EAL EHL °C Setting the upper alarm limit. At
alarm, the display shows:
A3
ELL °C Setting the lower alarm limit. At
alarm, the display shows:
A4
EHd
min.
Time delay for upper alarm.
ELd
min.
Time delay for lower alarm.
5. Temperature offset
(sensor
calibration)
CAL
CA K -5…+5 K
6. Alarm limits ALL FAS/ESC Setting of alarm limits.
Fixed/escorting.
FAS= fixed limits / ESC = limits
following the setpoint
7. No. of defrosts DEF
4 Number of defrosts in 24 hours.
Note: The numbers at each menu item refer to the numbers in the descriptions on
the following pages.
If a change of the setting is required, get access to the menu by pushing for
more than 3 seconds. The values are changed by pushing the or keys. The
new setting is saved by pushing . To exit the menu, push .