EasyManua.ls Logo

Gram BAKER M 950 - Optimizing the Energy Consumption

Gram BAKER M 950
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
765041776 Rev. 006 8
Optimizing the energy consumption
Correct set up gives the most effective operation.
The product should be located in a dry and adequately ventilated room.
To ensure efficient operation, it may not be placed in direct sunlight or against
heat-emitting surfaces. The product is designed to operate in an ambient
temperature between +16C and +40°C.
Do not keep the door open for too long.
Keep the condenser filter clean – to be cleaned at least every 2 weeks.
Do not set the temperature setpoint too low.
There must always be 20 cm of free space above the product, to ensure that
the heat from the condenser can be led away.
The product should be placed as close as possible up against the wall. For
products with a heating element in the tray on the cabinet backside, however
max. 75 mm from the wall.
Fig. 3
Max. 75 mm