Setting the temperature alarm limits
• Press and hold Prg/mute for more than 5 sec. during normal operation, in order to open the
parameter list. The display will show /c1
• Press Prg/mute . The first category of parameters, “Pro”, is shown
• Press UP until reaching category “ALn”, indicated by
the icon being lit on the display.
• Press Set parameter AA will be displayed.
• Press UP until reaching A1
• Press Set in order to adjust if AL (Alarm Low temperature threshold) and AH (Alarm High
temperature threshold) settings shall be (0 = relative to the cabinet temperature setpoints) or (1 =
absolute) default setting = 1
• Press Set in order to store the chosen setting and return to A1
• Press UP until reaching AL (Alarm Low temperature threshold)
• Press Set to make it possible to adjust AL using up and down
(adjustable between -50 and +50) Default setting = -50°C
• press Set in order to store the chosen setting and return to AL
• press UP until reaching AH (Alarm High temperature threshold)
• press Set to make it possible to adjust AH using up and down
(adjustable between -50 and +50) Default setting = +50°C
• press Set in order to store the chosen setting and return to AH
• press UP until reaching Ad (Alarm Delay time for AL and AH)
• press Set to make it possible to adjust Ad using up and down
(adjustable between 0 and 240 minutes) Default setting = 120 minutes.
• press Set in order to store the chosen setting and return to Ad
• Push and hold Prg/mute for more than 5 sec. in order to save changes, and the revert to the
main menu.