5.7. H-L MODE (CONTROL OF UPPER/LOWER LIMITS)
Keeping this key pressed
for more than one second activates or
deactivates the upper and lower limit control mode. For an
instant, the display shows the h-L On message to indicate that it
has been activated, or the h-L Of message to indicate that it has
been deactivated.
When the limit control is activated, a reading lights up in the bottom part of
the LCD display to signal whether the net weight on the plate is lower than
the LOW value or higher than the hIGh value. When the weight lies between
the two values, a sign appears indicating that the weight is in the interval
defined by the lower limit and the upper limit.
The colour of the display’s backlighting changes to red when the weight is
outside the interval defined by the upper and lower limit, and changes to
green when the weight is within said interval.
The 4 segments of this reading are activated proportionally to the difference
between the net weight on the scale and the value of the lower or upper
limit. The thicker segment indicates that the weight is below the value set as
the limit in a proportion of 100% or more.
Double-press on the H-L key to access the configuration and change the
lower and upper limits. The possible options are:
Value for the lower limit, including the decimal part.
Value for the upper limit, including the decimal part.
Yes / No: Activating the limit control when switching on
the unit.
hIGh
LOW
ACTIU