Page 8
Fire Bowls and Inserts Premium Line
Automated Operation
3.3 Installing the Fire Bowl
WARNING
Do not install near any combustibles such as wood structures,
fuels, clothing, fabrics, or dry vegetation.
Keep surrounding area clear of all debris such as paper, leaves,
pine-needles and other combustible materials.
WARNING
This unit is for outdoor use only.
Recommended CSA/AGA Clearances: Sides 4 ft / Top 6 ft
A LP gas regulator should never be installed in the fire bowl. It should be
installed by a gas expert in a remote location away from the heat source.
Install bowls out of the way of pedestrian traffic.
Installation shall be performed by a licensed contractor. All aspects of
installation must conform to local or national codes, or in the absence of
codes, with Natural Fuel Gas Code NFPA
®
54 / ANSI Z223.1.
The control panel and approved gas valve must be located where they can
be easily accessible so that the gas can be shut off quickly in case of an
emergency.
1. Install the control panel and gas piping as shown in Figure 3: Natural
Gas, Figure 4: Propane Gas, or Figure 5: Commercial Installation. Gas
lines must be clean and free from any dirt, debris, or contamination.
Note: Propane piping is different than natural gas piping (shown in
Figure 3 and Figure 4).
2. The gas piping must be installed underground between the control
panel and each re or water bowl, as shown in Figures 3 and 4.