Page #36 background imageLoading...
Page #36 background image
Figure 44: Right of Card and Private PIN
If using an RFID card or Private PIN to open door, then which door can be opened by the RFID card or Private PIN is
configured via “Card Management”, see above screenshot.
Keep Door Open
This feature allows users to set either an immediate or scheduled open door, this will allow usage scene like schools or similar
private or public places where the door needs to keep open at specific time window and closed otherwise. Also handy for
buildings or properties where a seminar needs to be hosted for some period or lunch breaks in a factory or company where
the door keeps open and no access log required then back to locked with authorized entry after that, by default it’s disabled.
Figure 45: Keep Door Open
There are two modes under this section:
Note
For all the settings, the final result of which door can be opened is the LOGIC INTERSECT OPERATION of ALL the sets of
conditions qualified.
Please refer to our Open Door Flow chart for better understanding of how to configure and control 2 Doors operation:
http://firmware.grandstream.com/GDS3710_opendoors_logic.pdf

Other manuals for Grandstream Networks GDS3712

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grandstream Networks GDS3712 and is the answer not in the manual?

Grandstream Networks GDS3712 Specifications

General IconGeneral
BrandGrandstream Networks
ModelGDS3712
CategoryIntercom System
LanguageEnglish

Related product manuals