EasyManua.ls Logo

Grant Vortex Pro - Electrical; General

Grant Vortex Pro
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
Figure 8-2: Kitchen/Utility models with 2 X 2-port valve control system
Electrical
L N E
240 V
50 HZ
Frost
Thermostat
Pipe
Thermostat
(if fitted)
Wiring Centre
1
2
3
4 5 6 7 8 9 10
1 3 4 N L
Cylinder
Stat
1
C
Room Stat
2 1
3
Pump
E
N
L
2-port
Zone Valve
Motor
HTG
2-port
Zone Valve
Motor
DHW
Grey
Blue Blue
Brown
Brown
Green/Yellow
Green/Yellow
Orange
Orange
Grey
1 2 3 4 5 6
L N E
7 8 9 10
E N L
Boiler
Terminal Block
Remove link 1 to 4 when
plug-in programmer is fitted
Grant 2-Channel
Wall Mounted Programmer
(Ref. ESKIT)
8.5 Control System Wiring Diagrams
Figure 8-1: Kitchen/Utility models with 3-port valve control system
1 2 3 4 5 6
L N E
7 8 9 10
E N L
L
N
E
Supply to
burner
Cylinder
Stat
1
C 2
L N E
240 V
50 Hz
Room
Stat
2 1 3
3-Port
Mid Position
Zone Valve
Pump
E
N
L
Blue
Green/Yellow
White
Grey
Orange
Frost
Thermostat
Pipe
Thermostat
(if fitted)
Wiring Centre
1 2 3 4 5 6 7 8 9 10
1 3 4 N L
Boiler Terminal Block
Remove link 1 to 4 when
plug-in programmer is fitted
Grant 2-Channel
Wall Mounted Programmer
(Ref. ESKIT)

Table of Contents