15
4. HACCP Hygiene and Operation Documentation
GRANULDISK Documentation Tool, GDTdirect™, is
an integrated function for the documentation of the
dishwashing machine’s operating parameters and
critical hygiene control points, HACCP.
• OperatingDataforthelast100washpro-
grammes run can be viewed directly in the
control panel window.
• Anexternalcomputercanbelinkedtothema-
chine and operating data stored in separate files
so that all historical data can be saved. Windows
2000 or Windows XP is a system requirement for
connecting an external computer. Please contact
your dealer for more information and installation.
Reading the Data through the control panel
1. Press STOP button (2), release it and wait 3
seconds.
2. Press “short programme” (4), five times.
3. Use button “eco programme” (3) or button
“normal programme (5) until you see “read
operating data” in the display. Confirm your
choice by pressing Confirm button (1).
4. Operating data for the last programme run is
shown in the display;
090121 15:19 SG 65/85 OK
The information is defined as follows;
• Date;090121 2009,January,21st
• Time;15.19 3.19p.m
• Programmetype;E,S,NequivalenttoECO,
Short and Normal programmes.
• Forcombimodetheprogrammesareindicated
by CE, CS and CN, for combi ECO, combi Short
and combi Normal.
• WashingwithGranules;indicatedbymeansof
a “G”, otherwise this box is left blank.
• 65;indicatestheaveragetemperatureinthe
wash tank during washing.
• 85;indicatesminimumtemperatureintherinse
tank during rinsing.
• OK;indicatesthattherinsewatervolumeis
correct in accordance with factory values; if
the set values have been changed, NA (not
applicable) is displayed.
NB! If the wash programme has been cancelled due
to an operating error or technical error, the tem-
perature indication is not included and “error” plus
an error code appears in its place.
090121 15:19 SG Error 103
5. To view information on programme run previ-
ously, scroll backwards and forwards in the list
using button “eco programme” (3) or button
“normal programme” (5).
6. To end scrolling and leave the list, press Confirm
button (1).
7. Press the STOP button (2) to return to operating
mode.