July 3, 2007 K2 Storage System Instruction Manual 105
Configuring RAID
represented by the single “Controller” node)
The Bind LUN dialog box opens showing all unbound disks for the controller
listed in the Available Disk list.
NOTE: Leave Full Bind selected. Do not uncheck it.
b. In the
LUN TYPE drop down box, select RAID 3.
c. In the Available Disks box, select five contiguous disks at the top of the list.
(TIP: Use ‘shift-click’ or ‘control-click’ to select disks.)
d. Click the add (arrow) button to add disks to the Selected Disks list.
NOTE: As an aid in identifying a disk module’s physical location, select it in the
Selected Disks list, then click
Identify Disks. This causes the disk drive light to flash.
e. Click
OK to close the Binding LUN dialog box and begin the binding process.
The Progress Report dialog box opens, showing the status of the binding
process.