July 3, 2007 K2 Storage System Instruction Manual 43
Preparing K2 Storage System clients
Power on the L2 RAID chassis
Your preparations for L2 RAID storage are now complete.
Preparing K2 Storage System clients
Any devices that function as iSCSI clients to the K2 Storage System must be prepared
with the following requirements:
One or more connections to the control network.
A static IP address for the control network.
For a Level 2 or 3 (non-redundant) K2 Storage System, one connection to the
media (iSCSI) network.
Additional steps that are required for Aurora Edits include the following:
Implement Aurora Edit security features.
Install SNFS software and K2 software.
POWER
SERVICE
K2
RAID STORAGE
!
Power Cords
(115V/230V)
Power-up Verification
Ready LEDs on RAID controllers are steady ON.
Front panel Power LED is ON, Service LED is OFF
after approximately 3 minutes.
Refer to the L2 RAID Instruction Manual if there is a
problem.
Power LED
Ready
LED
Ready
LED
Connect power cords, and turn on power as shown.
You must power-up any RAID Expansion chassis
prior to, or at the same time as the RAID Controller
chassis. Verify power-up as shown.
Service LED