EasyManua.ls Logo

GRASS VALLEY K2 - Page 180

GRASS VALLEY K2
394 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
180 K2 Storage System Instruction Manual July 3, 2007
Chapter 5 Installing the Level 3R Storage System
23.Enable Authentication traps. Type the following, then press Enter:
snmp-server enable traps authentication
This allows NetCentral to test the switch to verify that it can send its SNMP trap
messages to NetCentral.
24.Type the following, then press
Enter:
menu
When prompted, save the configuration by pressing the y key. The main menu
opens.
25.If you need a trunk for ISLs to gang switches together, use the following steps.
These steps illustrate trunking the last two ports for the two 10 Gig ISLs, which is
the recommended configuration for ISLs on all multi-switch K2 Storage Systems.
Refer to “Design considerations for Ethernet switches” on page 388 and consult
with your Grass Valley representative if your requirements deviate from the
recommended policy:
a. At the main menu, select
Switch Configuration and press Enter.
b. Choose selection
Port/Trunk Settings and press Enter.
c. Press the right-arrow key to choose
Edit, then press Enter.
d. Down arrow until at the bottom of the list of ports.
e. Right-arrow over to the Group column.
f. Use the Space bar and set the bottom 10 Gig port to
Trk1. Depending on the
switch model, this is port 26 or port A3.
g. Set the next port up also to
Trk1.
h. Press
Enter, then right-arrow to Save. Press Enter and revert to previous menu.
26.Select
Return to Main Menu and press Enter.
27.From the main menu, tab to
Command Line (CLI) and press Enter. The command
prompt appears.
28.Check the version of firmware currently installed on the switch. Type the
following, then press
Enter:
show flash
Information is displayed similar to the following example:
HP_iSCSI_switch1# show flash
Image Size(Bytes) Date Version
----- ---------- -------- -------
Primary Image : 3287779 03/15/05 M.08.66
Secondary Image : 3287779 03/15/05 M.08.66
Boot Rom Version: I.08.07
Current Boot : Primary
29.Check the Primary Image Version and refer to your K2 Storage System Release
Notes for information about currently supported versions. Then proceed as follows:

Table of Contents

Other manuals for GRASS VALLEY K2