23
9.1 Air Handler Dip Switch Settings
Default
factory setting is: Low air flow setting.
"ON" side is 0, the other side is 1.
For exam
ple:
Below is the default setting of 36K: 0010 0010
24K dip swit
ch:
Low air flow setting: 0101 (HEAT) /0101 (COOL)
Mid. air flow setting: 0110 (HEAT) /0110 (COOL)
High air flow setting: 0111 (HEAT) /0111 (COOL)
36K dip switc
h:
Low air flow setting: 0010 (HEAT) /0010 (COOL)
Mid. air flow setting: 0011 (HEAT) /0011 (COOL)
High air flow setting: 0100 (HEAT) /0100 (COOL)
48K dip switc
h:
Low air flow setting: 1011 (HEAT) /1011 (COOL)
Mid. air flow setting: 1100 (HEAT) /1100 (COOL)
High air flow setting: 1101 (HEAT) /1101 (COOL)
60K dip switc
h:
Low air flow setting: 1000 (HEAT) /1000 (COOL)
Mid. air flow setting: 1001 (HEAT) /1001 (COOL)
High air flow setting: 1010 (HEAT) /1010 (COOL)