EasyManua.ls Logo

Gree GFH09K3FI

Gree GFH09K3FI
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
95
U-Match Series DC
Inverter Service Manual
2.3 Interface
(1). GUHD09NK3FO/GUHD12NK3FO Mainboard
6
1
2
7 11
12
13
14
20
21
22
24
23
252627282930313233343536373840 394142
543 8 9
19
10
15
16
18
17
No. SILK-SCREEN INTERFACE INSTRUCTION No. SILK-SCREEN INTERFACE INSTRUCTION
1 LX_2 PFC reactor wire (yellow) 2 LX_1 PFC reactor wire (white)
3 W Compressor Phase W 4 V Compressor Phase V
5 U Compressor Phase U 6 DC-BUS (Reserved)
7 DC_MOTOR (Reserved) 8 - Compressor interface
9 DC-MOTOR1 Interface of outdoor fan motor 10 CN14/CN15 Interface of CPU board
11 E1 (Reserved) 12 E2
Grounding wire (yellow-
green lead-out wire)
13 AC-L Live wire input (red) 14 AC-N Neutral wire input (white)
15 O_HEAT_L (Reserved) 16 I_HEAT_N (Reserved)
17 O_HEAT_N (Reserved) 18 I_HEAT_L (Reserved)
19 H-PRESS Pressure switch 20 VA-1 Chassis electric heating belt
21 HEAT Compressor electric heating belt 22 4V 4-way valve
23 BACK_BUMP_L (Reserved) 24 BACK_BUMP_N (Reserved)
25 E3
Grounding wire (yellow-
green lead-out wire)
26 CN66
Communication interface between
indoor unit and outdoor unit
27 CN65 (Reserved) 28 HPP High pressure switch (reserved)
29 LPP Low pressure switch (reserved) 30 OVC-COMP Compressor overload switch
31 FA Electronic expansion valve 32 T-SENSOR1(In) (Reserved)
33 T-SENSOR1(Mid) (Reserved) 34 T-SENSOR1(Out) (Reserved)
35 T-SENSOR2(Tube) Tube temperature sensor 36 T-SENSOR2(Ambi) Ambient temperature sensor
37 T-SENSOR2(Exhaust) Discharge temperature sensor 38 T-SENSOR3 (Reserved)
39 SW4 (Reserved) 40 SW3 (Reserved)
41 A-DRIVE (Reserved) 42 JTAG1 (Reserved)

Table of Contents