Unit Control
● Water tank temperature can be set only when ―Hot water‖ is involved in the operation mode.
● The setting of ―Clock timer‖ only works once. If this setting is needed again, it should be set again.
● It will be deactivated when the unit is turned on manually.
● This function will be memorized upon power failure.
3.2.2.11 Temp. Timer
★
At the function setting page, access to the ―
Temp.timer
‖ setting page.
★
At the ―
Temp.time
r‖ setting page, it can be set to ―
On
‖ or ―
Off
‖.
★
Select ―
Period 1
‖/‖
Period 2
‖ and a window will pop up, where time period can be set. Then select
"WT-Heat1/WT-Cool 1/2‖ and also a window will pop up where temperature can be set‖.
[Notes]
●When ―
Weekly timer
‖, ―
Preset mode
‖,―
Clock timer
‖ ―
Temp. timer
‖ have been set at the same time,
then the latter takes the priority.
●This setting is valid only when the unit is turned on.
●Under the ―
Cool
‖ or ―
Cool+Hot water
‖ mode, the setting targets at ―
WT-Coo
l‖; while under the ―
Heat
‖
or ―
Heat+Hot water
‖ mode, the setting targets at ―WT-Heat‖.
●When start time of period 2 is the same as that of period 1, then the former takes prevalence.
●‖Temp.timer‖ is judged based on timer.
●During this setting, when temperature is set manually, then this setting will take prevalence.
●Under the ―Hot water‖ mode, this function will be reserved.
● This function will be memorized upon power failure.
3.2.2.12 Emergen. Mode
[Operation Instructions]
★
At the function setting page, set the mode to ―
Heat
‖ or ―
Hot water
‖.
★
At the function setting page, select ―
Emergen.mode
‖ and set it to ―
On
‖ or ―
Off
‖.
★
When ―
Emergen.mode
‖ has activated, the corresponding icon will appear at the upper side of the