Unit Control
menu page.
When the mode is not set to ―
Heat
‖ or ―
Hot water
‖, the display panel will tell ―
Wrong running mode!
[Notes]
The emergency mode is allowed on conditions that there is some error or protection and the
compressor has stopped at least for three minutes. If the error or protection has not been recovered,
the unit can access to the emergency mode through the wired controller (when the unit is off).
● Under the emergency mode,
Hot water
‖ or ―
Heat”
cannot be performed at the same time.
When the running mode is set to
Heat
‖, if
Other thermal”
or
Optional E-Heater
is set to
Without
‖, the unit will fail to access to the ―
Emergen. mode
‖.
●When the unit performs
Heat
under
Emergen. mode
and the controller detects
HP-Water
Switch
‖,
Auxi. heater 1
‖,
Auxi. heater 1
‖, and
Temp-AHLW
‖, this mode will quit at once. In the
same way, when errors mentioned above occur, ―
Emergen. mode
‖ cannot be activated.
●When the unit performs
Hot water
‖ under ―
Emergen. mode
‖ and the controller detects ―
Auxi.-WTH
‖,
this mode will quit at once. In the same way, when errors mentioned above occur,
Emergen. mode
cannot be activated.
●When this function has been activated,
Weekly timer
‖,
Preset mode
‖,
Clock timer
‖,and
Temp
timer
will be deactivated. Beside
On/Off
‖,
Mode
‖,
Quiet mode
‖,
Weekly timer
‖,
Preset mode
‖,
Clock timer
‖,and
Temp timer
‖ operation are unavailable.
●Under ―
Emergen. mode
‖, the thermostat does not work.
●This function can be activated only when the unit is turned off. If dosing so with the unit keeping ―
On
‖,
a window will pop up, saying
Please turn off the system first!
‖.
Floor debug
‖,
Disinfection
‖, and―
Holiday mode
cannot be activated at the same with this
function. When doing so, a window will pop up, saying
Please disable the emergen. mode!
‖.
● Upon power failure, ―
Emergen. mode
will back to ―
Off
‖.
3.2.2.13 Holiday Mode
[Operation Instructions]
At the function setting page, select ―
Holiday mode
and set it to ―On‖ or ―Off‖.
[Notes]
● This function can be activated only when the unit has been turned off, otherwise a prompt dialog box
will pop up, saying
Please turn off the system frist!
‖.
●When
Holiday mode
has been activated, the operation mode will automatically switch to
Heat
‖.
Mode setting and
On/Off
" operation through the controller will be unavailable.
●When
Holiday mode
has been activated, the controller will automatically deactivate the
Weekly
timer
‖ and
Preset mode
‖and
Clock timer
‖ and ―T
emp.timer
‖.
Under the
Holiday mode
‖, when the unit is under the control of room temperature, the set point
(room temperature for heating) should be set to 10°C; when it is under the control of leaving water
temperature, the set point (leaving water temperature for heating) should be 30°C.
When this function has been activated,
Floor debug
‖,
Emergen.mode
‖,
Disinfection
‖,
Manual
defrost”
,
Preset mode
‖,
Weekly timer
‖,
Clock timer
‖, and
Temp.timer
cannot be activated at
the same time, meanwhile a window will pop up, saying ―
Please disable the holiday mode!
‖.
●This function will be memorized upon power failure.
3.2.2.14 Preset Mode
[Operation Instructions]
At the function setting page, select ―Preset mode‖ and go to the corresponding setting page.