EasyManua.ls Logo

Gree GRS-CQ16Pd/NhG-M - Selection of the Water Tank; Specifications of the Water Tank; Volume Selection of the Water Tank

Gree GRS-CQ16Pd/NhG-M
135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Unit Control
Floor ceiling
type
213~2040
1.9~10.8
2.8~16.2
——
Cassette
type
480~1700
4.5~9
6.8~13.7
——
6 Selection of the Water Tank
6.1 Specifications of the Water Tank
SXVD200LCJ/A-K
220~240V-1N-50Hz
A single coil with the electric heater is integrated, used for floor heating system
SXVD300LCJ/A-K
SXVD200LCJ2/A-K
220~240V-1N-50Hz
Dual coils with the electric heater are integrated, used for floor heating system and the solar system
SXVD300LCJ2/A-K
SXVD200LCJ/A-M
380~415V-3N-50Hz
A single coil with the electric heater is integrated, used for floor heating system
SXVD300LCJ/A-M
SXVD200LCJ2/A-M
380~415V-3N-50Hz
Dual coils with the electric heater are integrated, used for floor heating system and the solar system
6.2 Volume Selection of the Water Tank
6.2.1 Selection Based on Water Consumption Per Capita
Building Type
Unit
Daily Water Consumption (L)
Water Temperature (°C)
House
Per person, Per day
40~80
60
Villa
Per person, Per day
70~110
60
6.2.2 Selection Based on Sanitary Utensils
Utensil Type
Daily Water
Consumption (L)
Water Temperature (°C)
Bathtub, Sprinkler system (with shower)
150
40
Bathtub, Sprinkler system (without shower)
125
40
Shower
70~100
37~40
Wash Basin
3
30
6.2.3 Selection of the Water Tank
Selection of the water tank should consider the flow rate of the shower head, duration of use per
person and daily water consumption.

Table of Contents

Other manuals for Gree GRS-CQ16Pd/NhG-M

Related product manuals