Service Manual
81
Installation and Maintenance
ProcedureSteps
7. Remove clapboard
8. Remove soundproof sponge
Remove the screws xing clapboard and
then remove the clapboard.
Remove the soundproof sponge wrapping
the compressor.
soundproof sponge
screw
clapboard
liquid
valve
gas valve
9.Valve liquid valve and gas valve
Unsolder the welding joint connecting the valve
with capillary and condenser; unsolder the
welding joint connecting the gas valve and air-
return pipe; remove the 2 bolts fixing the gas
valve to remove the gas valve.
Unsolder the welding joint connecting the liquid
valve and Y-shaped pipe; remove the 2 bolts
xing the liquid valve to remove the liquid valve.
Note:
Before unsoldering the welding joint, wrap the
gas valve with a wet cloth completely to avoid
damage to the valve caused by high temperature.