A/A DC INVERTER U-MATCH AIR CONDITIONERS MAINTENANCE
178
6. Remove the backside panel.
Remove the backside panel away
from the unit
Removal and Installation of Gas-liquid Separator and Compressor
Remark: Before removing the compressor, make sure that there is no refrigerant inside the pipe
system and that the power has been cut off.
Step Illustration
Handling
Instruction
7. Disconnect the
power cord of the
compressor
a. Open the cover of
the power supply box
with a wrench.
b. Disconnect the
power cord of the
compressor with the
pliers
c. Pull out the power
supply plug of the
compressor
2. 拆除汽液分离
器固定螺钉
用螺丝刀将汽液分离
器与隔板之间的固定
螺钉拆除。