A/A DC INVERTER U-MATCH AIR CONDITIONERS CONTROL
26
2.2 Dry Mode
Max.capacity out put:A×90%
3min
Firstly switch off to step 0
and then switch off step 60
150s atfer the compressor is stoped
180steps
Send out switch-off command
Acc.to controll
logic
capacity
demand
>0
send out dry
command
Indoor fan
(cooling)
4-way valve
3s
Xsteps
30s
ON
ON
ON
OFF
OFF
OFF
Outdoor fan
EXV
Compressor
OFF
Dry Mode
Acc.to controll
logic
60s
150s
The dry mode is basically same as cooling mode. The difference is that:
The indoor fan is fixed at low speed.
Max. capacity output: A×90%