A/A DC INVERTER U-MATCH AIR CONDITIONERS MAINTENANCE
187
14. Assemble the
electric box cover
Assemble the electric
box cover to correct
position
Use screwdriver to fix
the cover onto electric
box.
Removal and Installation of Electronic Expansion Valve
Remark : Before removing the compressor, make sure that there is no refrigerant inside the pipe system and
that the power has been cut off.
Step Illustration Handling Instruction
1.拆除电子膨胀阀线
用手松动电子膨胀阀
线圈
2.移开电子膨胀阀线
将电子膨胀阀线圈从
电子膨胀阀上去下、
移开
3 拆除电子膨胀阀
A.用气焊加热电子膨胀
阀两端连接管路后拔离电
子膨胀阀组件
B.焊接时要充氮保护,
氮气压力为 0.5±0.1kgf/c
㎡(相对压力)
C.加热时注意,以防周
围物料因高温烧毁