A/A DC INVERTER U-MATCH AIR CONDITIONERS MAINTENANCE
220
Disassembly of fan and motor components
Remark: Make sure that the power supply is cut off before disassembling and protect all the parts during
disassembly, especially the fastening screws for fans.
Step Illustration Handling Instruction
2. Disassembly
of fans
Unscrew the 2 screws of
coupling, take out the
rotating shaft and louver,
then loosen the tighten
screw of louver to
remove the louver.
3. Disassembly
of bearing
fixing plates
Unscrew the 3 screws
and 2 nuts of support to
remove the mounting
support
4. Disassembly
of motor
Loosen the 2 screws of
the motor attaching
clamp, remove the
motor attaching clamp
and motor attaching
clamp subassembly to
remove the motor.
Disassembly of right and left fixing plates
Remark: Make sure that the power supply is cut off before disassembling and protect all the parts during
disassembly.
Step Illustration Handling Instruction
Disassembly of
right and left
fixing plates
Disassemble the bolts on
right and left fixing
plates with tools. (As is
shown by the arrow in
the graph.)