GREINER MULTILINE NEXT DC - User Manual

GREINER MULTILINE NEXT DC
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...

Table of Contents

Questions and Answers

  • K
    Kelly RollinsSep 9, 2025
    Why does GREINER Medical Equipment battery drain so fast?
    • L
      Leah MaxwellSep 9, 2025
      If battery operation with sufficient charge is only possible for a short time on your GREINER Medical Equipment, further inspection is needed, as the battery life limit may have been reached. If necessary, replace the battery.
  • D
    dsmithSep 12, 2025
    What to do if potential equalisation does not function properly on GREINER Medical Equipment?
    • M
      Michelle BonillaSep 12, 2025
      If the potential equalisation on your GREINER Medical Equipment does not function properly, further inspection is needed, as the equipotential bonding pin may be damaged or not present. If necessary, replace the equipotential bonding pin.
  • M
    Margaret OrtegaSep 13, 2025
    Why won't the LED reading lamp turn on for GREINER Medical Equipment?
    • E
      Evan MillerSep 13, 2025
      If the LED reading lamp on your GREINER Medical Equipment cannot be switched on, further inspection is needed. If necessary, plug in the connection cable or replace the LED reading lamp. The cause may be a defective LED reading lamp or a connection cable that is either plugged out or defective.
  • R
    Robert MccoySep 15, 2025
    What to do if central locking of the 4 castors does not function properly on GREINER Medical Equipment?
    • D
      Diane WilliamsonSep 15, 2025
      If the central locking of the 4 castors on your GREINER Medical Equipment does not function properly, further inspection is needed. If necessary, replace the castors. The cause may be defective castors or a brake linkage that is bent or defective.
  • E
    Erica IbarraSep 17, 2025
    What to do if single-braked castor(s) do(s) not function(s) properly on GREINER Medical Equipment?
    • P
      pewingSep 18, 2025
      If the single-braked castors on your GREINER Medical Equipment do not function properly, further inspection is needed. If necessary, replace the castors. The cause may be defective castors.

Summary

Safety Guidelines for MULTILINE NEXT DC

Safety Inspection Procedures

Details legal requirements and recommendations for safety checks.

Personal Safety and Operator Responsibility

Emphasizes user instruction and operator responsibilities.

Intended Use and Environment

Specifies the medical couch's designated purpose and environment.

Commissioning the MULTILINE NEXT DC Couch

Safety Instructions for Commissioning

Highlights safety precautions and user responsibilities during setup.

Couch Preparation for Assembly

Describes the steps to unpack and prepare the couch for assembly.

Pre-Use and Re-Assignment Checks

Outlines essential checks before first use or after storage.

Operating the MULTILINE NEXT DC Couch

Safety Instructions for Operation

Details critical safety measures during couch usage.

Hand Control Functions

Explains the functions and operation of the device's primary control interface.

Hand Control Security

Describes the procedure to enable or disable couch movements.

Basic Couch Position

Details how to return the couch to its default neutral position.

Relax Couch Position

Explains how to achieve a comfortable reclining posture for the patient.

Bed Position (Flat)

Describes the function to flatten the couch into a bed-like state.

Shock Position for Emergencies

Details the emergency function for rapidly positioning the patient.

Driving and Maneuvering the Couch

Provides instructions for safely moving the couch, including braking.

Braking Systems Overview

Describes the systems used to secure the couch in a stationary position.

Central Locking Castor Operation

Details the operation of a common central braking system.

Central Locking with Directional Control

Explains combined central locking and directional castor features.

Single-Braked Castor Operation

Describes the operation of individual locking castors.

Patient Sitting and Standing Assistance

Provides guidance for safe patient ingress and egress.

Cleaning and Disinfection Procedures

Routine Couch Cleaning

Provides instructions for routine cleaning of the couch surfaces.

Troubleshooting Common Issues

Actuator Initialisation Procedure

Explains how to reset actuator positions when errors occur.

Control Unit Reset Process

Describes the procedure to reset the couch's main control unit.

Troubleshooting Problem Table

Lists common problems, causes, and solutions for electrical and mechanical issues.

Decommissioning and End-of-Life Handling

Checks Before Recommissioning

Details checks required after storage before returning to service.

GREINER MULTILINE NEXT DC Specifications

General IconGeneral
Product TypeAutomated Chemistry Analyzer
ModelMultiline NEXT DC
ApplicationClinical chemistry analysis
ThroughputUp to 400 tests per hour
BrandGREINER
Measurement TechnologyPhotometric, ISE (ion selective electrode)
Sample TypeSerum, Plasma, Urine
Data TransferLIS connectivity, USB
Battery TypeNot applicable (mains powered)
Operating Conditions15-30°C
Measurement RangeInstrument specific for each parameter