Questions and Answers

  • M
    Mr. Tony RossAug 12, 2025
    Why can I ping GridConnect NET485 but not Telnet to port 9999?
    • B
      Brenda BrownAug 13, 2025
      If you can ping the GridConnect Adapter but cannot Telnet to port 9999, it might indicate an IP address conflict on your network. To resolve this, turn off the device server and use the following commands in your computer's DOS prompt: 'ARP -D X.X.X.X' (replace X.X.X.X with the device server's IP address), followed by 'PING X.X.X.X' (again, using the device server's IP address). If you receive a response after the ping, it confirms a duplicate IP address. If there's no response, use the serial port to check if Telnet is disabled.
  • C
    Colleen PachecoAug 16, 2025
    What to do if GridConnect NET485 is not communicating with the serial device?
    • A
      awolfAug 16, 2025
      If the GridConnect Adapter isn't communicating with the serial device, the serial settings might be incorrect. Ensure that the serial settings for both the serial device and the device server match. The default settings for the device server are RS-232, 9600 baud, 8 character bits, no parity, 1 stop bit, and no flow control. For NET485, you must change the setting to RS422 or RS485.
  • J
    Jonathan MirandaAug 20, 2025
    How to fix not responding setup mode on GridConnect Adapter?
    • C
      Christopher HamiltonAug 20, 2025
      If pressing Enter after the 'Press Enter to go into Setup Mode' message on port 9999 of GridConnect Adapter doesn't work, it's because you must press Enter within 5 seconds of seeing the message. Telnet to port 9999 again and press Enter as soon as you see the message.
  • N
    nsnowAug 25, 2025
    What to do if GridConnect NET485 Telnet window does not respond?
    • J
      Joseph TurnerAug 25, 2025
      If the Telnet window of GridConnect Adapter does not respond for a long time when assigning an IP address, the device server might not have a network connection. Check if the Link LED is lit. If it is not lit, the device server does not have a network connection.
  • N
    nchungAug 27, 2025
    How to fix cannot ping NET485 DHCP name on GridConnect Adapter?
    • R
      Renee FoxAug 27, 2025
      If you cannot ping or connect to the NET485 DHCP name of GridConnect Adapter, the DHCP server might not be automatically setting the DHCP name in DNS on the network. Contact the Network Administrator to manually add the NET485 to DNS.
  • S
    Scott HarveyAug 31, 2025
    What to do if ARP method and Telnet to port 1 fails on GridConnect NET485?
    • S
      Sydney BrewerAug 31, 2025
      When assigning an IP address to the GridConnect Adapter using the ARP method and then attempting to Telnet to the device server through port 1, the connection will fail because the ARP method only creates a temporary password. Telnet back to Port 1, wait for it to fail, then Telnet to port 9999 again, ensuring you press Enter within 5 seconds.
  • T
    Tony OrtegaSep 4, 2025
    Why no response when entering setup mode via serial port on GridConnect NET485 Adapter?
    • K
      Kristen AllenSep 4, 2025
      Setup Mode via the serial port is NOT supported on the NET485 GridConnect Adapter. The unit is able to receive data but it cannot transmit, since the TXEN enable pin is not accessible to the boot firmware.
  • W
    William JohnsonSep 8, 2025
    What to do if ARP entry addition failed on GridConnect NET485?
    • R
      richard78Sep 8, 2025
      If the 'ARP entry addition failed: 5' message displays when issuing the ARP –S command in Windows for GridConnect Adapter, your user login likely lacks the necessary permissions. Have your IT department log you in with sufficient rights.

Summary

2. Introduction and Specifications

2.3 Hardware Features and Specs

Covers jumpers, power supply, Ethernet LEDs, and technical specifications.

3. Getting Started

3.1 Quick Rundown

Overview of initial setup steps including connection and IP assignment methods.

3.3 Methods of Assigning the IP Address

Describes methods for assigning an IP address: DHCP, Device Installer, AutoIP.

3.4.1 Channel 1 Configuration

Configures serial port parameters like protocol, baud rate, and flow control.

3.4.2 Configurable Pin Settings

Configures the function of the NET485's hardware pins.

3.6 Server Configuration

Configures network parameters like IP address, gateway, and netmask.

3.7 Channel 1 Configuration (Serial Port Parameters)

Detailed serial port settings including Baudrate, I/F Mode, Flow, and Connect Mode.

3.10 Security Settings

Security configurations including SNMP, Telnet, encryption, and passwords.

4. Monitoring the Network

4.1.2 Monitor Mode Commands

Lists available commands for diagnostics within Monitor Mode.

5. Updating Firmware

6. Troubleshooting

6.1 Problems and Error Messages

Diagnosing and fixing common problems and error messages encountered.

GridConnect NET485 Specifications

General IconGeneral
InterfaceRS-485
Product TypeSerial to Ethernet Converter
Ethernet10/100 Mbps
Power Supply5V DC
Operating Temperature0°C to 70°C
Baud Rate300 bps to 230.4 kbps
Operating Voltage5V DC
ProtocolsTCP, UDP, IP, ICMP, HTTP, DHCP, ARP, DNS
Connector TypeTerminal Block

Related product manuals