18
04
Power saving mode
enable/disable
Saving mode disable (default)
If disabled, no matter connected load is low or high, the on/off status of
inverter output will not be effected.
Saving mode enable
If enabled, the output of inverter will be off when connected load is pretty
low or not detected.
05
Battery type
AGM (default)
Flooded
Lithium (only suitable when communicated with BMS)
User-Defined
If “User-Defined” is selected, battery charge voltage and low DC cut-off
voltage can be set up in program 19, 20 and 21.
User-Defined 2suitable when lithium battery without BMS
communication
If “User-Defined 2” is selected, battery charge voltage and low DC cut-off
voltage can be set up in program 19, 20 and 21. It is recommended to set
to the same voltage in program 19 and 20(full charging voltage point of
lithium battery). The inverter will stop charging when the battery voltage
reaches this setting.
06
Auto restart when overload
occurs
Restart disable (default)
Restart enable
07
Auto restart when over
temperature occurs
Restart disable (default)
Restart enable
08
Output voltage
*This setting is only
available when the inverter
is in standby mode (Switch
off).
230V (default)
220V
240V
208V
09
Output frequency
*This setting is only
available when the inverter
is in standby mode (Switch
off).
50Hz (default)
60Hz
10
Number of series
batteries connected
(e.g. Showing batteries are connected in 4 series)