PV Module Selection:
When selecting proper PV modules, please be sure to consider below parameters:
1.
Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter.
2.
Open circuit Voltage (Voc) of PV modules should be higher than start-up voltage.
Please follow below steps to implement PV module connection:
1.Remove insulation sleeve 10 mm for positive and negative conductors.
2.Insert PV panel positive and negative cables into MC4 terminal, then connect positive pole(+)of connection
cable to positive pole(+)of PV input connector, connect negative pole(-)of connection cable to negative pole(-)
of PV input connector.
3.Make sure the wires are securely connected.
Final Assembly
After connecting all wiring, please put bottom cover back by screwing four screws as shown below.
Communication Connection
Please use supplied communication cable to connect to inverter and PC. Follow on-screen instruction to install
the monitoring software. For the detailed software operation, please check user manual of software. The
monitoring software is downloadable from our website www.ginverter.com.