22
Display Information
The LCD display information will be switched in turns by pressing “UP” or DOWN” key. The selectable
information is switched as below order: voltage, frequency, current, power, firmware version.
Setting Information
LCD display
AC Input voltage
If it flashes, it indicates that the
input voltage of the generator is
displayed at this time, and the
current, power and frequency
displayed after turning the page are
also the input parameters of the
generator.)
Output voltage
Load percentage
LeftPV1 input voltage
Right: PV2 input voltage
Battery voltage
Warning or Fault code
(Default Display Screen)
AC Input frequency
Output frequency
Load power in VA
LeftPV1 energy sum in KWH
Right: PV2 energy sum in KWH
Battery percentage
Warning or Fault code
AC Input current
Output current
Load percentage
LeftPV1 input current
RightPV2 input current
Battery charging current
Warning or Fault code