KM 251 en Installation
V1.0 23
5.2.2 Installation Examples and Tips
Picture of optimal installation
1i Dosing tank
2i Electric agitator
3i Extraction device
4i Suction pulsation damper
5i Dosing pump
6i Overflow valve
7i Pressure retention valve
8i Pulsation damper
9i Measuring glass
10i Injection unit
Type
Stroke
value
Nominal width of
suction line
Maximum suction line
length [m]
251-2,4 14 DN 8 8
251-5 29 DN 8 8
251-13 63 DN 8 3
251-19 96 DN 8 1,5
251-24 120 DN 8 1
251-2,3 14 DN 8 8
251-4,9 29 DN 8 8
251-12 63 DN 8 3
251-18 96 DN 8 1,5
251-23 120 DN 8 1
251-2,2 14 DN 8 8
251-4,5 29 DN 8 8
251-11 63 DN 8 3
251-17 96 DN 8 1,5
251-21 120 DN 8 1
1i
2i
3i
4i
5i
6i
7i
9i
10i
8i
max. 1m