17
10. Technical data
Supply voltage
1 x 230 V ±10%, 50 Hz, PE.
See nameplate.
Input power
P1 = 80 W.
Input current
I = 0.7 A.
Back-up fuse
10 A slow-blowing fuse on the mains side and earth
leakage circuit breaker according to IEC 345.
Buzzer
• Sound pressure level: 80 dB(A).
• Control voltage: 230 V.
Head
Maximum 5.4 metres (tolerance ±10% at +20°C).
Flow rate
Maximum 630 l/h (tolerance ±10% at +20°C).
Liquid temperature
• 0°C to +35°C.
• For short periods: Maximum +80°C for 1 minute.
Ambient temperature
During operation: 0°C.
In stock:
• In dry rooms frost-proof down to –20°C.
• Lifting stations containing condensate:
In dry rooms with a temperature above 0°C.
(There must be no risk of frost.)
pH value
2.7 or above.
Maximum density
1000 kg/m³.
Operating mode
Intermittent operation, S3: 15% according to DIN
EN 0530 T1 (i.e. runs for 1.5 minutes and is stopped
for 8.5 minutes).
Motor protection
• Thermal switch: +120°C.
• Insulation class: B.
Potential-free contact
• Changeover switch.
• Breaking capacity: 6 (1.5) A 250 VAC.
• Connections: Flat plugs 6.3 x 0.8.
Enclosure class
IP 20.
Dimensions
• Tank volume: 2.6 litres.
• Storage volume: 0.85 litre.
• H x L x B = 199 x 245 x 171 mm.
See also dimensional sketch, fig. 2.
Weight
2.3 kg.
10.1 Other technical data
See nameplate.
Fig. 9 Performance curve
11. Disposal
This product or parts of it must be disposed of in an
environmentally sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest
Grundfos company or service workshop.
TM02 7446 1204
0 2 4 6 8 10 Q [l/min]
0
1
2
3
4
5
H [m]
Conlift
Subject to alterations.