8. Calibration
It is important that the pump is calibrated after
installation to ensure that the correct value
(ml/h or l/h) appears in the display.
The calibration can be carried out in two different
ways:
• Direct calibration.
The dosed quantity of 100 strokes is measured
directly. See section 8.1 Direct calibration.
• Check calibration. See section 8.2 Check
calibration.
Fig. 27
Operating display
without changes
Set value.
See section 8.2
Operating display Operating display
The pump
performs
100 dosing
strokes