FIELD CONVERSION FROM FLOOD OIL TO OIL MIST BEARINGS
There are several types of oil mist configurations available from various manufacturers. The following
instructions are for conversion of flood oil lubrication to a continuous purge oil mist system.
(a)
Install oil mist inlet connections (14) inch at top inboard and outboard tapped connections on bearing
frame. SEE FIGURE
C.
(b)
Remove oil drain plug (408A) at bottom center of frame% inch NPT plug. Install drain connection
for oil mist system.
(c)
Refer to oil mist manufacturer's system instructions for operation and adjustment.
Figure C. Oil Mist system connection
(MTP Frame Illustrated)