EasyManua.ls Logo

Grundfos RSI - Startup Wizard Parameter Description

Grundfos RSI
182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.2 Startup wizard parameter description
Once you have connected power to your RSI, follow
these instructions to easily set up your drive.
You can have your AC drive equipped with
a graphical keypad.
Name Description Factory setting User setting
Language Selection Select language English
Real time clock setting:
Daylight saving
1)
(P5.5.5)
Select region:
Russia
US
EU
OFF
Real time clock setting:
Time
1)
(P5.5.2)
Set the time in hh:mm:ss format
Real time clock setting:
Year
1)
(P5.5.4)
Set the year in yyyy format
Real time clock setting:
Date
1)
(P5.5.3)
Set the date in dd.mm. format
Startup wizard Select startup wizard Yes
Motor type Select motor technology Induction motor
Motor Nom Voltage Motor rated voltage Variant-dependent
Motor Nom Freq Motor rated frequency 50
Motor Nom Speed Motor nominal speed 2850 RPM
Motor Nom Current Motor rated current Size-dependent
Motor Cos Phi Motor power factor Size-dependent
Motor Nom Power Motor rated power Size-dependent
Output Sinus Filter Select if sine-wave filter is used or not Yes
Pump Selection Grundfos pump family SP
Module MP Voltage Vmp maximum power point voltage 33
Modules in series Number of solar panels in series 18
Application
Select application Solar or PID with
solar
Solar standard
1)
This parameter only appears if a battery is installed.
The User settings column is left blank to allow users
to write down their own input settings.
After modifying the parameters in the table
above, the inverter needs to be stopped
and started again to update the
parameters.
No record is made of undervoltage fault