The Grundfos RSI contains a preloaded Grundfos
motor library for instant use.
1.1 Specific functions of Grundfos RSI
The dedicated application software was developed to
drive a Solar Pump with an optimized MPPT
(Maximum Power Point Tracking) for RSI supplied by
Solar Panels.
The MPPT is based on 4 parallel algorithms:
Feed-Forward Controller (to follow the radiation
variations)
Correction Controller (to compensate the
temperature variations)
Oscillation Damping Regulator (to prevent the
panel entering in the "current source" branch of
the characteristic)
Local Maxima logic (to prevent the regulator from
being trapped in a local maximum lower than
absolute maximum)
Features
The MPP Tracker controls DC voltage reference
in order to find the maximum power.
Extensive wizards for start-up, PID-control used to
facilitate commissioning
"Funct" button for easy change between Local
(keypad) and Remote control place. The remote
control place is selectable by parameter (I/O or
Fieldbus)
8 preset frequencies
Motor potentiometer functions
2 programmable ramp times, 2 supervisions and 3
ranges of prohibited frequencies
Control page for easy operation and monitoring of
the most essential values.
Fieldbus data mapping
Automatic reset
Different pre-heat modes used to avoid
condensation problems
Maximum output frequency 320 Hz
Real-time clock and timer functions available
(optional battery required). Possible to program 3
time channels to achieve different functions on the
drive (e.g. Start/Stop and Preset frequencies)
External PID-controller available. Can be used to
control e.g. a valve using the AC drive I/O
Sleep mode function which automatically enables
and disables drive running with user defined
levels to save energy.
2-zone PID-controller (2 different feedback
signals; minimum and maximum control)
Two setpoint sources for the PID-control.
Selectable with digital input
PID setpoint boost function
Feedforward function to improve the response to
the process changes
Process value supervision
Maintenance counter
Underload protection can be managed by
measuring Motor torque (standard sensorless
mode) or by measuring the water flow with a flow
meter sensor. This sensor can be an analogue
signal or a digital input. With this sensor it is
possible to measure the water flow [litres/min] and
the total volume of the water flow [m
3
].
Sleep mode can be enabled or disabled with a
parameter.
Digital inputs can be used to measure water levels
(minimum and maximum).