EasyManuals Logo

Grundfos SLV Series User Manual

Grundfos SLV Series
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
English (GB)
32
The supply cable resistance depends on the cable diameter.
Resistance per running metre of cable: 1.5 mm
2
= 0.012 Ω.
Resistance per running metre of cable: 2.5 mm
2
= 0.007 Ω.
13. Disposal
This product or parts of it must be disposed of in an
environmentally sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest Grundfos company
or service workshop.
Subject to alterations.
4-pole motor Cable connection
Power P
2
[kW]
Power P
1
[kW]
Voltage
[V]
Starting method Thermal protection
Cable cross section
[mm
2
]
Conductors /
plug pins
1.1 1.5 3 x 380-415 DOL Thermal switch 1.5 7/7
1.1 1.5 3 x 400-415 DOL Thermal switch 1.5 7/7
1.3 1.8 3 x 380-415 DOL Thermal switch 1.5 7/7
1.3 1.8 3 x 400-415 DOL Thermal switch 1.5 7/7
1.5 2.1 3 x 380-415 DOL Thermal switch 1.5 7/7
1.5 2.1 3 x 400-415 DOL Thermal switch 1.5 7/7
2.2 2.9 3 x 380-415 DOL Thermal switch 1.5 7/7
2.2 2.9 3 x 380-415 Y/D Thermal switch 1.5 10/10
2.2 2.9 3 x 400-415 DOL Thermal switch 1.5 7/7
3 3.7 3 x 380-415 DOL Thermal switch 1.5 7/7
3 3.7 3 x 380-415 Y/D Thermal switch 1.5 10/10
3 3.7 3 x 400-415 DOL Thermal switch 2.5 7/7
4 4.9 3 x 380-415 Y/D Thermal switch 2.5 10/10
4 4.9 3 x 400-415 DOL Thermistor 2.5 7/10
5.5 6.5 3 x 380-415 Y/D Thermal switch 2.5 10/10
5.5 6.5 3 x 400-415 DOL Thermistor 2.5 7/10
7.5 9.0 3 x 380-415 Y/D Thermal switch 2.5 10/10
7.5 9.0 3 x 400-415 DOL Thermistor 2.5 7/10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos SLV Series and is the answer not in the manual?

Grundfos SLV Series Specifications

General IconGeneral
BrandGrundfos
ModelSLV Series
CategoryWater Pump
LanguageEnglish

Related product manuals